Skip to content

Latest commit

 

History

History
131 lines (107 loc) · 7.02 KB

README.md

File metadata and controls

131 lines (107 loc) · 7.02 KB

OneFLOW tests

The test/ directory contains test runners, suite definitions, test cases, and checked-in numerical baselines. Generated reports and run artifacts do not belong here.

Directory policy

test/
├── README.md
├── suites/
│   ├── ci-serial.txt
│   ├── cpu-serial.txt
│   └── grid-serial.txt
├── baselines/
│   ├── README.md
│   ├── build_residual_db.py
│   ├── verify_residual_db.py
│   └── residual-baseline.json
├── test.py
├── cfd/
│   └── <CFD case directories>/
└── grid/
    └── <grid case directories>/
  • Add reusable suite lists under test/suites/ with stable names. Suite entries are paths relative to the runner's working directory; the canonical CPU CI job stages cases under matching relative paths.
  • Keep accepted numerical references under each case's autotest/ directory.
  • autotest/compare.txt lists text outputs compared line by line with numeric tolerance. An optional autotest/binary.txt lists binary outputs compared byte for byte; each reference is stored in autotest/ using the output basename. Use byte comparison only for deterministic binary artifacts: compiler, endian, metadata, or serialization differences can make it too strict for portable grid regression. Grid cases should also validate the reloaded grid's dimensions, finite coordinates, bounding box, and topology.
  • An optional autotest/required.txt lists outputs that must be created as non-empty files during the current run. The runner removes these outputs before launching the case, preventing stale artifacts from making a failed grid conversion look successful. This is suitable for the first-stage grid conversion smoke test while a reviewed ASCII reference is being prepared. Before launching the solver, the runner also rejects unsafe case-relative paths, duplicate comparison basenames (which would alias one stored reference), and cases with no output assertions. A zero exit code by itself is never a passing test.
  • Keep structured residual baselines under test/baselines/; regenerate them only when the accepted numerical result changes.
  • Write generated logs, results, reports, and temporary files outside test/.
  • Maintain project reports under docs/reports/ using stable filenames.
  • Do not create a new dated report for every regression run. CI run evidence belongs in workflow artifacts; durable conclusions update the stable report.

The regular ci-serial.txt suite covers the established CFD residual cases and the existing Plot3D grid conversion. Gmsh-to-CGNS conversion is validated through the shared conversion template grid/conversion/gmsh_to_cgns, the C++ reader/conversion integration tests, and the Mesh-to-CFD Validation Workbench. The obsolete GUI-only experimental manual runner has been removed; the conversion template and its MSH fixtures remain part of the supported conversion and validation workflow.

CPU regression baseline

The canonical CFD residual baseline contains the five existing OneFLOW CFD cases under test/cfd/. The CPU-serial workflow also runs a separate grid-conversion smoke suite (suites/grid-serial.txt) because grid cases do not produce CFD residual files:

Case Coverage Reference outputs
plateuns2dslau2 2-D laminar flat plate, SLAU2, viscous flux and wall boundary handling aero.dat, res.dat, flatplate_cf.dat, flatplateflow.dat, wallaero.dat
rae2822_roe_sa 2-D transonic airfoil, Roe flux and Spalart-Allmaras turbulence aero.dat, wallaero.dat, res.dat, turbres.dat
m6wingroe_sa 3-D wing, Roe flux and Spalart-Allmaras turbulence aero.dat, wallaero.dat, res.dat, turbres.dat
plateuns2dslau2_34950_35000 continuation flat-plate case from the accepted restart aero.dat, res.dat, flatplate_cf.dat, flatplateflow.dat, wallaero.dat
turbplateuns2droe_sa turbulent flat plate, Roe flux and turbulence model aero.dat, wallaero.dat, res.dat, turbres.dat, turbplate_cf.dat, turbplateflow.dat

The checked-in files under each case's autotest/ directory are the CPU reference results. Accelerator implementations must first match these results through the existing numeric comparison tolerance before performance results are considered.

The top-level test/test.txt was a duplicate of suites/cpu-serial.txt; suite files under suites/ are now the sole case-list source. autotest/compare.txt names the expected text-output comparison manifest explicitly, alongside binary.txt and required.txt.

Run only this baseline suite from the test directory:

python3 test.py \
  "mpirun -np 1" \
  "/path/to/OneFLOW" \
  suites/cpu-serial.txt \
  baselines/residual-baseline.json \
  1e-15

The fifth argument is an optional residual absolute tolerance override. The canonical database covers all residual channels for every one of the 50 steps. Iteration columns and row counts must match exactly; strict residual validation uses abs(actual - reference) <= 1e-15. ONEFLOW_RESIDUAL_DB and ONEFLOW_RESIDUAL_TOLERANCE provide environment variable equivalents. Set ONEFLOW_RESIDUAL_TEST_OUTPUT=1 for the strict run; the solver then writes max-digits10 values to the same res.dat and turbres.dat paths used by the normal run.

The repository also contains a manual-only Kunshan workflow:

.github/workflows/kunshan-regression.yml

It performs an SSH/Slurm authorization preflight before creating a remote directory or submitting a job. If the required Kunshan secrets, pinned host key, private key, or remote configuration are unavailable, the workflow stops with an explicit error. See ci/kunshan/README.md for the required secrets and private cluster configuration.

The backend framework defaults to CPU and does not redirect numerical operators yet. Runtime selection can be requested with ONEFLOW_ACCEL_BACKEND; requesting an adapter that has not been built fails with a clear error rather than silently falling back to CPU. The CMake cache also accepts HIP, CUDA, and KOKKOS as reserved backend names so future adapters can be added without changing the solver-facing interface.

The maintained delivery report is:

docs/reports/delivery/oneflow-gpu-backend-delivery.md

Contract traceability

The Contract Workbench contains a typed Case-domain description for cfd/plateuns2dslau2 at tools/verification/contracts/case/laminar_flat_plate_slau2.json. It links the existing suite, solver inputs, output comparison manifest, canonical residual database, and Blasius reference profiles without replacing the suite or runner.

The catalog performs static consistency checks only. A catalog PASS means that declared references and metadata are structurally consistent; it does not mean the CFD case has just been executed. The regression runner remains the authority for execution and numerical comparison. The Blasius files are retained scientific references but are not currently compared automatically by test.py; the contract records this limitation explicitly.