Skip to content

Security: otfabric/s7commctl

Security

SECURITY.md

Security

Supported versions

Version Supported
Latest release Yes
Older releases No

Reporting a vulnerability

If you believe you have found a security vulnerability in s7commctl, please report it responsibly.

  • Do not open a public GitHub issue for security-sensitive bugs.
  • Email security@otfabric.io, or open a private security advisory on GitHub: Security → Advisories → Report a vulnerability.

Include a clear description, steps to reproduce, and the impact. We will acknowledge your report and work with you on a fix and disclosure timeline.

Security-related considerations

  • Network and PLC access: s7commctl connects to Siemens S7 devices over TCP (port 102). Use it only on networks and targets you are authorized to access. The commands that connect to one PLC warn on stderr when the target IP appears publicly routable, and discover warns when its --cidr range holds publicly routable addresses; --no-exposure-warning suppresses either in authorized environments. The warning does not stop the command.
  • Proxies: --proxy sends the connection, and the PLC traffic in clear text, through the SOCKS5 proxy you name; use only a proxy you control, such as an SSH jump host. The exposure warning checks the PLC's address, not the proxy's.
  • Writes: The write command can modify PLC memory and requires explicit --dangerous. Unless --force is set, it asks for confirmation with a prompt that names the length, type and value, the address, area, DB, offset and bit, the IP and port, and the rack and slot or TSAPs; these can come from S7COMMCTL_* variables. --type bool requires --bit and writes that one bit; without --bit it is refused before the prompt. --type string reads the STRING's declared maximum (byte 0) first, refuses a longer value and leaves byte 0 unchanged. Use with care in production.
  • Device-supplied text: identification texts come from the device. Text and table output (and --quiet) of identify, fingerprint and profile print non-printable characters and invalid UTF-8 as \xNN; JSON escapes them as JSON does.
  • Protection level: when fingerprint or diagnostic cannot read the protection level, they report it as unknown (null and protection_error in JSON, unknown with the reason in text and table output), and fingerprint reports write_likely_allowed: false.
  • Credentials: The tool does not store passwords; S7 over ISO-on-TCP (port 102) typically relies on network segmentation and PLC protection levels rather than application-level authentication. Ensure targets are not exposed to untrusted networks.

Listeners

sniff and replay are the only commands that accept connections:

Command Default --listen Accepts
sniff 127.0.0.1:15102 The first client; its frames are decoded and printed
replay 127.0.0.1:1102 The first client; it receives the scripted responses

The defaults accept local clients only. Neither listener authenticates or encrypts: the first client that connects is the client, and a later client is not served. --listen :PORT (or S7COMMCTL_SNIFF_LISTEN, S7COMMCTL_REPLAY_LISTEN) listens on every interface, so that any host that can reach the port can be that client; use it only on a network you control, with a host firewall that admits the intended peer. Before v0.10.0 the defaults were :15102 and :1102, every interface.

Limits

Input Limit Beyond it
A TPKT frame (sniff, replay, pcap-decode) Version 3, 7 to 65535 octets (the 16-bit TPKT length) Another header is not a frame: sniff and replay stop with an error, pcap-decode skips one octet and looks for the next header
A packet of a pcap capture 262144 octets captured pcap-decode stops with an error; frames decoded before it are printed
Memory of pcap-decode One packet at a time, and per direction of a connection less than one TPKT maximum pending after each packet Captures of any size are read packet by packet
Waiting for the next frame sniff 120 s, replay 300 s The command ends with exit 5 (timeout)
Waiting for the PLC's answer to one request --request-timeout (0: no limit; negative: refused with exit 2), since v0.12.0; when it is not set, --timeout, default 5000 ms (0 or negative: no limit), since v0.11.0 The command ends with exit 5 (timeout) and the connection is closed; a read reports status timeout
A write --type string value 254 octets, and the STRING's declared maximum (byte 0, read before the write) Refused with exit 2; nothing is written
Consecutive record samples that fail with a transport error or timeout --max-failures, default 5 (0: no limit) record stops: the connection is lost, exit 4 or 5

For protocol and safety behavior, see README.md and PROTOCOL.md.