| parameter | default | description | use with... |
|---|---|---|---|
me_code |
mess |
Name of the master equation code. Only mess (MESS) is supported. |
|
mess_command |
mess |
Command to run MESS, an executable with optional arguments, e.g. "/opt/MESS/bin/mess". Used for local runs, queue scripts and the written run scripts; relative paths are resolved from me/. Quote paths with spaces; shell variables are not expanded. |
MESS |
TemperatureList |
[300, 400, ..., 2000] |
See MESS manual. | MESS |
PressureList |
[7.6, 76, 760, 7600, 76000] |
See MESS manual (Torr). | MESS |
EnergyStepOverTemperature |
.2 | See MESS manual | MESS |
ExcessEnergyOverTemperature |
30 | See MESS manual. | MESS |
ModelEnergyLimit |
400 | See MESS manual. | MESS |
CalculationMethod |
direct | See MESS manual. | MESS |
ChemicalEigenvalueMax |
0.2 | See MESS manual. | MESS |
EnergyRelaxationFactor |
200 | See MESS manual. | MESS |
EnergyRelaxationPower |
0.85 | See MESS manual. | MESS |
EnergyRelaxationExponentCutoff |
15 | See MESS manual. | MESS |
epsilon |
0. | The epsilon parameter from the Lennard-Jones potential in units of epsilon_unit. |
MESS |
epsilon_unit |
K |
Unit of the epsilon in the Lennard-Jones potential. Can be K, cm-1, or J/mol. |
MESS |
sigma |
0. | The sigma parameter from the Lennard-Jones potential in Angstrom. | MESS |
collider |
He |
The symbol for the collider, He, N2, Ar, O2 or H2O. |
MESS |
me |
0 |
1: write the master-equation input (me/mess_*.inp) after the calculations, 0: do not. |
|
run_me |
0 |
1: also run MESS and wait for the result; with queuing: "local" MESS runs on the current machine, otherwise it is submitted. 0: write the input and the run script only. |
MESS |
me_skip_vdW |
0 |
0: product complexes found by KinBot (deeper than vdW_detection, see Reaction search) are wells of the MESS network, with barrierless exits to the separated products. 1: leave them out and connect each inner TS directly to the separated products. The search and optimization of the complexes is unchanged; the inner TS keeps the complex energy as its tunneling reference. Rates can differ between the two settings, since the complex's stabilization and capture/redissociation are gone with 1. |
MESS |
correct_submerged |
0 |
1: raise every barrier that lies below a connected bound well to that well's ground energy (MESS requires this). A TS below separated fragments is not raised. |
MESS |
Output: one input per connected well network, me/mess_<n>.inp, listed in me/mess_networks.json; MESS's microcanonical output goes to me/mess_<n>.micro. Every species name carries its stereochemical suffix (see Stereochemistry), and the symmetry factors include the optical counting described there. Different stereochemical pathways of the same reaction are combined in a MESS Union. With queuing: "local" and run_me: 1, MESS is executed and its exit status checked; a solver failure is reported separately from a KinBot failure.
Parameters marked with an asterisk (*) must not change when a run is restarted, see Restarting.
Getting started
Input keywords
- Input file and keyword index
- General
- Reactant
- Stereochemistry
- Reaction search
- Reaction types
- Conformers and rotors
- Quantum chemistry
- Computational environment
- Master equation
- Uncertainty quantification
- VRC-TST
Results