Skip to content

Master Equation Calculations

jzador edited this page Oct 21, 2026 · 6 revisions
parameter default description use with...
me_code mess Name of the master equation code. Only mess (MESS) is supported.
mess_command mess Command to run MESS, an executable with optional arguments, e.g. "/opt/MESS/bin/mess". Used for local runs, queue scripts and the written run scripts; relative paths are resolved from me/. Quote paths with spaces; shell variables are not expanded. MESS
TemperatureList [300, 400, ..., 2000] See MESS manual. MESS
PressureList [7.6, 76, 760, 7600, 76000] See MESS manual (Torr). MESS
EnergyStepOverTemperature .2 See MESS manual MESS
ExcessEnergyOverTemperature 30 See MESS manual. MESS
ModelEnergyLimit 400 See MESS manual. MESS
CalculationMethod direct See MESS manual. MESS
ChemicalEigenvalueMax 0.2 See MESS manual. MESS
EnergyRelaxationFactor 200 See MESS manual. MESS
EnergyRelaxationPower 0.85 See MESS manual. MESS
EnergyRelaxationExponentCutoff 15 See MESS manual. MESS
epsilon 0. The epsilon parameter from the Lennard-Jones potential in units of epsilon_unit. MESS
epsilon_unit K Unit of the epsilon in the Lennard-Jones potential. Can be K, cm-1, or J/mol. MESS
sigma 0. The sigma parameter from the Lennard-Jones potential in Angstrom. MESS
collider He The symbol for the collider, He, N2, Ar, O2 or H2O. MESS
me 0 1: write the master-equation input (me/mess_*.inp) after the calculations, 0: do not.
run_me 0 1: also run MESS and wait for the result; with queuing: "local" MESS runs on the current machine, otherwise it is submitted. 0: write the input and the run script only. MESS
me_skip_vdW 0 0: product complexes found by KinBot (deeper than vdW_detection, see Reaction search) are wells of the MESS network, with barrierless exits to the separated products. 1: leave them out and connect each inner TS directly to the separated products. The search and optimization of the complexes is unchanged; the inner TS keeps the complex energy as its tunneling reference. Rates can differ between the two settings, since the complex's stabilization and capture/redissociation are gone with 1. MESS
correct_submerged 0 1: raise every barrier that lies below a connected bound well to that well's ground energy (MESS requires this). A TS below separated fragments is not raised. MESS

Output: one input per connected well network, me/mess_<n>.inp, listed in me/mess_networks.json; MESS's microcanonical output goes to me/mess_<n>.micro. Every species name carries its stereochemical suffix (see Stereochemistry), and the symmetry factors include the optical counting described there. Different stereochemical pathways of the same reaction are combined in a MESS Union. With queuing: "local" and run_me: 1, MESS is executed and its exit status checked; a solver failure is reported separately from a KinBot failure.

Parameters marked with an asterisk (*) must not change when a run is restarted, see Restarting.

Clone this wiki locally